GM50L Blower Abnormal Noise & Rotor Rubbing Repair

1. Project Overview
Industry: Wastewater Treatment
Equipment: GM50L Roots Blower
Failure Type: Abnormal Noise / Rotor Rubbing
Year: 2024
2. Project Background
The client operates a wastewater treatment plant where stable blower performance is essential for aeration processes.
During operation, the GM50L blower developed abnormal noise and vibration, indicating internal mechanical issues.
3. Problem / Failure Analysis
Abnormal noise during operation
Increased vibration level
Evidence of rotor contact with side plate
Risk of progressive internal damage
4. Root Cause
Detailed inspection revealed:
Rotor misalignment inside the casing
Reduced internal clearance
Mechanical interference between rotor and side plate
Possible long-term wear combined with installation deviation
5. Our Solution
Procetek implemented a precision repair and alignment solution:
Complete disassembly of the blower
Inspection of rotor, casing, and side plates
Correction of rotor alignment
Restoration of internal clearance
Reassembly with precision tolerance control
Dynamic testing after repair
6. Scope of Work
Equipment dismantling
Fault diagnosis and clearance measurement
Rotor alignment correction
Component inspection and adjustment
Reassembly and functional testing
7. Before & After Condition
Before Repair
Blower with abnormal noise and vibration
Rotor contact marks visible




During Repair
Disassembly and inspection process






After Repair
Reassembled blower with corrected alignment
After repair, the blower operated smoothly with no abnormal noise or vibration.
8. Results
Abnormal noise completely eliminated
Vibration reduced to normal operating level
Restored internal clearance and mechanical stability
Avoided full equipment replacement cost
9. Why It Worked
Accurate fault diagnosis
Precision alignment capability
Strong control of internal tolerances
Experience in blower mechanical systems
10. Conclusion
This case demonstrates that precision mechanical correction can effectively restore blower performance without replacement, significantly reducing cost.
11. Call to Action
If your blower shows abnormal noise or vibration,
👉 contact us for diagnostic and repair solutions.



Comments